KATEGORI
KATEGORI
Adres:
1-1009, National Industrial Design Park, No. 599 Jianzhu Road, Binhu, Wuxi, Jiangsu, China, 214062
Telefon:Tell: +86 21 51096910
E-posta:
Email: info@welsobio.com
Sorgulama
kuluçka çalkalayıcı
ürün detayları
The Thermo Incubator Shaker can be used for vibration culture of large-capacity cells, fermentation, bacteria, etc. The Welso WIS500 has a humanized design, a small footprint, and a large screen for easy operation and use. It also has an ultraviolet sterilization function, and the shaking plate can be pulled out for easy access to culture. The container can be washed with a high-pressure water gun and has a slow start and slow stop function, which can effectively prevent damage to bacteria or cells caused by excessive shearing force during start and stop.
Features
•Large capacity of 450L.
•10" high resolution LCD touch screen with simultaneous display of all parameters.
•Large space for accommodating 5L erlenmeyer flasks.
•Stackable up to 2 units maximum.
•CO₂ infrared sensor and effective inlet filter.
•Triple eccentric drive for stable and reliable shaking.
Specifications
Model | WIS5000 | WIS5000C | WIS5005 | WIS5005C |
Product Name | Stackable Incubator Shaker,Touch Screen | Stackable Incubator Shaker With CO₂ Controller, Touch Screen | Stackable Incubator Shaker,Touch Screen, Shaker Diameter 50mm | Stackable Incubator Shaker With CO₂ Controller, Touch Screen, Shaker Diameter 50mm |
Shaking | ||||
Orbit Diameter | 26mm | 50mm | ||
Speed | 0 (stop), 30 - 300 rpm | |||
Speed Accuracy | ±1rpm | |||
CO₂ | ||||
CO₂ Sensor | NA | IR | NA | IR |
CO₂ Control Range | NA | 0-20% | NA | 0-20% |
CO₂ Control Accuracy | NA | ±0.1% | NA | ±0.1% |
Recover Time After Open Door 30s on Temp | ≤6min(@37℃) | |||
Recover Time After Open Door 30s on CO₂ | NA | ≤6min(@5%) | NA | ≤6min(@5%) |
Temperature | ||||
Temp.Range | Room Temp.Minus 18℃~60℃(lowest Temp. is 4℃) | |||
Temp.Accuracy | 0.1℃ | |||
Temp.Uniformity | ±0.3℃(@37℃) | |||
Heating Power | ≤850w | |||
Cooling Power | 70~230w | |||
Humidity | ||||
Humidity Type | NA | Evapor Naturally | NA | Evapor Naturally |
Max.Humidity | NA | 95% | NA | 95% |
General | ||||
Platform Dimensions | 900*560mm | |||
Capacity | 450L | |||
Max.Load | 20KG | |||
Magnetic Driver | Yes | |||
Programmable Segments | 12 Segments | |||
Illumination | LED Lamps on Left and Right Walls | |||
Disinfection | UV Lamps on Left and Right Walls | |||
Door Open Direction | Downward | |||
Data Display | Temp, Speed | Temp, Speed CO₂, RH | Temp, Speed | Temp, Speed, CO₂, RH |
Display | 10" High-Res Color Touch Screen | |||
Timer | 0-999h59min | |||
USB Export Data | Yes | |||
Data Display on Interface | In 7 Days | |||
Operating Data Storage Cycle | More Than 912 Days | |||
Data Storage Interval | 1min | |||
Data Stored | Time, Temp, Speed, Status | Time, Temp, Speed, Status, CO₂ RH | Time, Temp, Speed, Status | Time, Temp, Speed, Status, CO₂, RH |
Auto-Defrost | Yes | |||
Auto Screen Off | Yes | |||
Auto Screen Lock | Yes | |||
Third Platform Height | 1296mm | |||
Platform with Rails | Yes | |||
Noise Level | ≤55dB(When Compressor Is Running) | |||
Auto-run after Power Recovery | Yes | |||
Power | ≤950w | ≤1000w | ≤950w | ≤1000w |
Power Supply | AC 220V±22V, 50Hz/60Hz | |||
RH Control | NA | Optional(10% Above Ambient Humidity, Up To 90%) | NA | Optional(10% Above Ambient Humidity, Up To 90%) |
Mobile Monitor and Control by WIFI | Optional | |||
PC monitor and Control by RS485 | Optional | |||
Window Cover | Optional | |||
Net Weight | 325kg | 325kg | 325kg | 330kg |
Internal Working Height | 430mm | |||
External Dimensions | 1400*886(600+80 Feet High)mm |
Stack Dimensions
İlişkisi tavsiyeler